Series RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter

Optional LCD Display, Replaceable Sensors

General Information :

The SERIES RHP-E/N Wall Mount Humidity/Temperature/Dew Point Transmitter is the most versatile room transmitter on the market. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. The humidity and the dew point are measured using a capacitive polymer sensor that completely recovers from 100% saturation. The humidity and dew point can have either a current or voltage output, while the optional temperature output can be a current, voltage, RTD or thermistor. For models with current or voltage for the temperature output, the temperature range is field selectable.

  • Air economizers
  • Room comfort monitoring
  • Greenhouse monitoring

Relative Humidity Range: 0 to 100% RH.
Temperature Range: -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors. -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors.
Dew Point Temperature Range: -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) field selectable ranges.
Accuracy: >RH: Model RHP-2XXX ±2% 10-90% RH @ 25°C, Model RHP-3XXX ±3% 20-80% RH @ 25°C;

Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C);

RTD Temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C);

Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C).

Hysteresis: ±1%.
Repeatability: ±0.1% typical.
Temperature Limits: Operating: -40 to 140°F (-40 to 60°C); Storage: -40 to 176°F (-40 to 80°C).
Compensated Temperature Range: -4 to 140°F (-20 to 60°C).
4-20 mA Loop Powered Output: >Power Requirements: 10-35 VDC.

Output Signal: 4-20 mA, 2 channels for humidity/solid state temperature sensor models (loop powered on RH).

Switch selectable RH/dew point. Switch selectable normal or reverse output.

0-5/10V Outputs: >Power Requirements: 15-35 VDC or 15-29 VAC. Output Load: 5 mA max., 2 channels for humidity/solid state temperature sensor models.

Switch selectable 0-10V/2-10V or 0-5V/1-5V output. Switch selectable RH/dew point. Switch selectable normal or reverse output.

Solid State Band Gap Temp Sensor Output Ranges: Switch selectable, -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C). (See R-T Lookup Table).
Response Time: 15 seconds.
Electrical Connections: Screw terminal block.
Drift: <1% RH/year.
RH Sensor: Capacitance polymer.
Enclosure Material: Warm gray polycarbonate.
Display: Optional LCD, backlit on 0-5/10V models. Switch selectable %RH or dew point, °F/°C.
Display Resolution: RH: 1%; Temperature: 0.1°F (0.1°C); Dew Point: 1°F (1°C).
Weight: 0.3 lb (0.14 kg).
Agency Approvals: CE.

  • Field selectable relative humidity or dew point output
  • Field replaceable relative humidity and temperature sensor elements
  • Universal analog outputs
  • Integral or service tool LCD display options
  • Two housing designs to match North American and European aesthetics

CE Approval